Making your own Connecting Cable
You can also make the 16-pin connecting cable yourself. To do so, select a 2 x 8-
pin socket housing (e.g. AMP 0-926476-8), contacts (e.g. AMP 2-167301-4 or
AMP 0-166500-2) and cable type with the following characteristics:
Tab. 4.14:
Requirements for a 16-pin connecting cable
Core pairs x cores
Stranded
Wire diameter, core
Screening
Connection Points
If the PBX is connected to the network or universal building cable installation indi-
rectly via a main distribution board, the following connection points will have to
be provided in the main distribution board:
Tab. 4.15:
Connection points per interface
Interface
S/T
a/b
AD2
T2
Ethernet interface
V.24
General call
Interface
Switch group 1
Freely connectable relay
Door intercom interface 1
Door intercom interface 2
HBT_20321104_04/B0_en
4 x 4
Yes
0.4...0.6 mm
Not necessary
Connection points
per interface
4
2
2
4
Crossed patch cable Cat. 5 (see
4
Patch cable, progressive Cat. 5
9
2
2
6
16
Connecting cable (see Page 4.92)
16
16-pin connecting cable (see Fig.
ascom
Ascotel 2025/2045/2065
Connecting cable
16-pin connecting cable
(see Page 4.30)
16-pin connecting cable
(see Page 4.30)
16-pin connecting cable
(see Page 4.30)
Page 4.45)
(see Page 4.90)
Modem cable (see Page 4.81)
16-pin connecting cable
(see Page 4.30)
Connecting cable (see Page
4.100)
Connecting cable (see Page
4.102)
4.23)
Connecting the PBX
Number of con-
nectors
1
1
1
2
2
2
1
1
4.31