Configuring a Local Signal Destination on an Ethernet Inter-
face
A PC (with the System Event Manager) connected either directly to the Ethernet
interface or to the basic system via a LAN (LAN connection) can be configured as
the local signal destination.
The event messages are displayed in PC format.
The "Local Output Interface" must be set on "IP Destination" in the Fault & Main-
tenance Manager.
The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager:
• Destination: Ethernet
• IP address of the PC
• TCP port number (the initialization value is 1062; if the value is changed in the
SEM, it will have to be altered accordingly on the PBX side.)
See also:
Information on the connecting cables can be found in "Ethernet Inter-
face", Page 4.86.
HBT_20321104_07/B0_en