Ascotel 2025/2045/2065
Call to the Public Network via a Gateway PINX with Overflow Routing and
"Automatic CLIP = no"
Subscriber B (330) on PINX 2 calls subscriber F on the public network via PINX 3
as all the available communication channels between PINX 2 and PINX 1 are busy.
PINX 3 does not have a DDI number for subscriber B.
"Automatic CLIP = no" is set in the configuration subscriber of subscriber B. The
CLIP settings of the subscriber configuration are used:
• CLIP number = 55 555 55 53
• NPI = E.164
• TON = national
Region 50
Region 60
55 555 55 53
55 555 55 53
330
F
B
55 555 55 53
330
PINX 2
PINX 3
055 555 55 53
022 222 22 22
Source PINX
Gateway PINX
haz0690aaena0
Fig. 2.24:
Example 5: Subscriber B calls subscriber F (excerpt from Fig. 2.19)