ASCOM Ascotel 2025 System Manual page 692

Isdn telecommunications system
Table of Contents

Advertisement

Configuration with 2 Radio Units
Test radio unit B
Fig. 3.27:
Configuration with 2 radio units
Used for:
• Determining the optimum overlap for the two coverage ranges
• Increasing efficiency by measuring simultaneously in 2 coverage ranges
– Planning work carried out by 2 people
– Calls with the test handsets are possible (only via the same test radio unit)
All the equipment is always duplicated. This makes for more efficient planning
within the team. The standard handsets are used for determining the field
strength. They indicate the field strength of one or more radio units in the range
from 0 to 65 dBµV. For this, the equipment switches to a look-around mode in
which the handset provides a selection of all the radio units received. Up to 4 radio
units can now be selected and measured with one another. For measurement-
related reasons this is however not recommended.
To be able to determine the transitions, it is useful to have 2 radio units in opera-
tion at the same time. In some cases you may also want to prevent the changeover
from being signalled. The handover behaviour of the standard handset is selecta-
ble.
A second handset type is also available to each planner: the test handset for set-
ting up call connections. For a call connection we need to select test radio unit A
or B.
HBT_20321104_03/B0_en
Stationiary coverage
range A
Test
handset 1
Mobile planner 1
230 VAC
ascom
Ascotel 2025/2045/2065
Stationiary coverage
range B
Mobile planner 2
Test
handset 2
Standard
handset 1
Test radio unit A
haz0341aaenc0
Planning DECT Systems
Standard
handset 2
3.61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ascotel 2045Ascotel 2065

Table of Contents