Omron V7 Brochure & Specs

Omron V7 Brochure & Specs

New v7 inverters
Hide thumbs Also See for V7:

Advertisement

NEW V7 INVERTERS
I m p r o v i n g o n p e r f e c t i o n
Decent ra li sed co ntro l
»
E x p a n d e d f u n c t i o n a l i ty
»
» I n t e l l i g e n c e o n b o a r d
Advanced Industrial Automation

Advertisement

Table of Contents
loading

Summary of Contents for Omron V7

  • Page 1 NEW V7 INVERTERS I m p r o v i n g o n p e r f e c t i o n Decent ra li sed co ntro l » E x p a n d e d f u n c t i o n a l i ty »...
  • Page 2 Market standard 4,00 Conventional inverter Omron-Yaskawa 2,00 1 year 5 years Noisy operation Silent operation 0,00 C.Frq. (KHz) Ro b u st I G BTs T h e s e c r e t i n s i d e...
  • Page 3: New Features

    - 2 Motors change function unrivalled dynamic control, including fast braking and high- - Free I/O’s setting to be used precision positioning at stop. From full speed to full stop is from host controller achieved faster than market standard inverters. Moreover, this...
  • Page 4 PLC functionality. It not only equips the V7 with extra functionality for a broad range of digital control tasks, it also leads to significant savings by eliminating the need for a separate PLC.
  • Page 5: System Configuration

    V7 IP65 • Compact size • Easy wiring • Built-in filter (Class B) Customized software* • The inverter software can be customized to meet specific application. Examples: • Traverse sofware S-9381. *For detailed information please refer to case software section. Ratings •...
  • Page 6: Specifications

    3-phase 200..230 V 50/60 Hz and frequency Allowable voltage -15%..+10% fluctuation Allowable frequency fluctuation Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current 400 V class 40P2 40P4 40P7 41P5 42P2...
  • Page 7 Ground fault Protected by electronic circuit (operation level is approx. 250% of rated output current) RUN lamp stays ON or digital operator LED stays ON until the DC bus voltage becomes 50 V or less. Power charge indication (Charge LED is provided for 400 V)
  • Page 8: Digital Operator

    Used to reset the inverter when an error occurs. V7 IP65 types have digital operator without frequency adjuster. The status of the local/remote selection indicator can be only monitored while the inverter is in operation. Any RUN comand input is ignored while this indicator is lit.
  • Page 9 Dimensions IP 20 type 0.1 to 4 Kw 4 M4 2 M4 (0.34) (0.34) Figure 1 Figure 2 Dimensions in mm Max. applicable Inverter model Cooling Voltage class Figure Weight kg motor output kW CIMR V7AZ method 0.12 20P1 0.25...
  • Page 10 IIP65 type 0.55 to 4 Kw 6 . 4 3x PG25 Figure 4 Max. Dimensions in mm Inverter Voltage applicable Weight Cooling model Figure class motor method CIMR V7TZ output kW 0.55 B0P405 Self cooled B0P705 Single-phase 200 V B1P505...
  • Page 11 IP65 type 0.55 to 4Kw (with option frame accessory attached) 6 . 4 Figure 5 3x PG25 2x PG12 Max. Dimensions in mm Inverter Voltage applicable Weight Cooling model Figure class motor method CIMR V7TZ output kW 0.55 B0P405 Self cooled...
  • Page 12: Installation

    S– V7 IP65 types are built-in filter. A housing is required when using the CN2 terminal on the back side of the digital operator. 1m analog input cable (code no. 3G3MV-PCN-CN2) is available for housing on request : shielded wire...
  • Page 13: Main Circuit

    Power supply terminal for +12V (allowable current: 20 mA max.) frequency setting 0 to +10 VDC (20 kΩ) or 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) (resolution 1/1000) Speed frequency reference Frequency reference common Voltage input (between terminals 1 and 3): 0 to 10 VDC (input impedance: 20 kΩ)
  • Page 14: Inverter Heat Loss

    Side spaces Top and bottom spaces 1. Always provide enough space for the main circuit or control lines including cable gland. 2. If installing inverters next to one another, provide a minimum spacing of 60mm Frequency inverters Varispeed V7...
  • Page 15: Ordering Information

    LKEB_ CDBR_B ERF150WJ_ * V7 IP65 types are built-in filter inverters. Communication unit PLC option unit *See note *See note * Option frames are needed for V7 IP65 type. Varispeed V7 200 V 400 V Specifications Model Specifications Model 1x200 V 0.12 Kw...
  • Page 16 3G3MV-PFI1030-SE 3G3MV-PFI1030-E B4P0 3G3MV-PFI1040-SE 3G3MV-PFI1040-E 40P2 / 40P4 3G3MV-PFI3005-SE 3G3MV-PFI3005-E 40P7 / 41P5 / 42P2 3G3MV-PFI3010-SE 3G3MV-PFI3010-E 3-Phase 400 VAC 40P4 3G3MV-PFI3020-SE 3G3MV-PFI3020-E 45P5 / 47P5 3G3MV-PFI3030-SE 3G3MV-PFI3030-E * V7 IP65 types are built-in filter inverters. Frequency inverters Varispeed V7...
  • Page 17 • Host controller: TrajeXia, MCH or MP series. option card Option frame accessory is needed for V7 IP65 types when communications option units are used. For V7 IP65 types with DeviceNet communication, SI-N1/V7 should be used. Please refer to TrajeXia, MCH or MP series section for host controller technical information.
  • Page 18 9.3 (0.37) 9.3 (0.37) deep 3.5 (0.14) (1.20) 15.5 (0.61) 70 (2.76) 72606-CVS31060 Blank cover ----- 3G3IV-PEZZ0838BA Digital operator case same as JVOP-144 without operator Digital operator extension cable 3G3IV-PCN126 ----- 1 meter 3G3IV-PCN326 3 meters ----- 3G3IV-PCN329-E PC configuration cable...
  • Page 19 780 75 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I20E-EN-02 In the interest of product improvement, specifications are subject to change without notice.
  • Page 20 B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.omron-industrial.com Austria Hungary Spain United Kingdom Tel: +43 (0) 1 80 19 00 Tel: +36 (0) 1 399 30 50...

Table of Contents