Settings Which Change With The Control Mode (A1-02) - Omron VARISPEED L7 Manual

Hide thumbs Also See for VARISPEED L7:
Table of Contents

Advertisement

Settings which change with the Control Mode (A1-02)

Parameter
Name
Number
C3-01
Slip compensation gain
C4-02
Torque compensation delay time
C5-01
ASR P gain 1
C5-02
ASR Integral time 1
C5-03
ASR P gain 2
C5-07
ASR gain switching frequency
C5-09
ASR P gain 3
C5-10
ASR Integral time 3
E1-04
Max. Frequency
E1-06
Base Frequency
E1-08
Mid. output frequency voltage (VB)
E1-09
Min. output frequency (FMIN)
E1-10
Min. output frequency voltage (VMIN)
E1-13
Base Frequency
E2-05
Mid. output frequency (FB)
E3-06
Mid. output frequency voltage (VB)
E3-07
Min. output frequency (FMIN)
E3-08
Min. output frequency voltage (VMIN)
F1-01
PG constant
F1-05
PG rotation direction
F1-04
AO-12 Channel 1 Signal selection
L1-01
Motor protection selection
L4-01/03
Speed agreement detection level
L4-02/04
Speed agreement detection width
L8-09
Output open phase detection selection
n5-01
Feed forward control selection
o1-03
Frequency monitor/reference display
o1-04
V/f pattern frequency parameter unit
S1-01
Zero speed level
*1. The given values are for a 400 V class Inverter.
*2. Can be set only if Hiperface is selected as interface.
Setting Range
Unit
0.0 to 2.5
0 to 10000
msec
1.00 to 300.00
0.000 to 10.000
sec
1.00 to 300.00
0.0to 120.0
1.00 to 300.00
0.000 to 10.000
sec
0 to 120.00 Hz
20 to 7200 rpm
rpm
0 to 120.00 Hz
20 to 7200 rpm
rpm
*1
0.0 to 510.0
0 to 120.00 Hz
20 to 7200 rpm
rpm
0.0 to 510.0
0.0 to 510.0
0 to 120.00 Hz
*1
0.0 to 510.0
0.0 to 120.0
*1
0.0 to 510.0
0 to 60000
*2
512, 1024
, 2048
0 or 1
1 to 56
1 to 75
0 to 3
0 or 5
0 to 120.00
0.0 to 100.0
0.0 to 20.0
0.0 to 40.o
0 to 2
0 or 1
0 or 1
0 to 39999
0 or 1
0.00 to 10.00
Factory Setting
Open Loop
V/f Control
Vector
A1-02=0
A1-02=2
-
1.0
1.0
200
20
-
-
-
-
-
-
-
-
i
-
-
-
-
-
-
-
Hz
50.00
50.00
-
-
Hz
50.00
50.00
-
-
V
37.4
25.0
Hz
0.5
0.3
-
-
V
19.4
5.0
V
0.0
0.0
Hz
2.5
3.0
V
30.0
26.4
Hz
1.2
0.5
V
18.0
4.8
-
-
-
-
-
-
-
-
-
-
-
2
2
-
-
-
1
1
-
-
-
Hz
0.0
0.0
%
-
-
Hz
2.0
2.0
%
-
-
-
2
2
-
-
-
-
-
-
-
0
0
-
-
-
Hz
1.2
0.5
Closed
Closed
Loop Vec-
Loop Vec-
tor A1-
tor (PM)
02=3
A1-02=5
1.0
1.0
-
-
40.00
12.00
0.500
0.300
20.00
6.00
0.0 Hz
2.0 %
40.00
12.00
0.500
0.300
50.00
-
-
150
50.00
-
-
150
-
-
0.0
-
-
0
5
-
-
-
400
-
-
-
-
0.0
-
-
-
1024
-
-
2048
0
-
-
1
2
-
-
5
1
-
-
5
0.0
-
-
0.0
2.0
-
-
4.0
2
-
-
0
1
0
0
1
0
1
0.1
0.5
61
5-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents