Running A Dmm Test - Agilent Technologies AuroraPresto User Manual

Table of Contents

Advertisement

Running a DMM Test

The DMM Test is made up of five sub-tests.You can use the
DMM tests to measure: voltage, resistance, capacitance and
current on analogue lines.
-1- From the Physical Layer screen select DMM Tests
-2- Select the sub-test you want and press ENTER.
-3- Connect
-4- Press ESC to exit the test.
Issue 7 - 05/02
and press ENTER to display the following options:
DC Voltage—use to measure ADSL line voltage.
AC Voltage—use to measure AC voltage.
Resistance—Use this to test for resistive
problems which can indicate cable shorts.
Capacitance—Use this to test for capacitive
problems which can indicate insulation problems
and breaks in the cable.
DC Current—Use this to check the current
drawn to test the cable characteristics.
AuroraPresto
example, the following screen displays the Resistance
test screen.
To perform another DMM test, repeat from step 2
above.
Section 3 - Physical Layer Tests
to the device to be tested. For
4-23

Advertisement

Table of Contents
loading

Table of Contents