The following table explains the results.
Time
Rx kbits
BER
Bit_errs
Tx kbits
ES
Injected
Sync-
Loss
Status
Note
No synchronisation is required to start the counter in
TX Only mode.
Issue 7 - 05/02
DSL ATM BERT Results Display
The length of time the test has been
running, in hours, minutes and
seconds.
The number of kilobits of data received
while the test is running and the
patterns are synchronised.
The Bit Error Rate, displayed in
exponential format.
The number of bit errors received while
the test is running and the patterns are
synchronised.
The number of kilobits of data
transmitted while the test is running
and the patterns are synchronised.
The number of Errored Seconds. An
errored second is any second during
which one or more bit errors are
received.
The number of errors injected.
The number of occasions when pattern
synchronisation has been lost.
The status of the BERT
synchronisation.