Error Messages
Error/Warning
ID
WID-3279
WID-3280
WID-3282
WID-3283
WID-3284
WID-3285
WID-3286
WID-3287
WID-3288
EID-3290
EID-3291
EID-3292
EID-3293
Error/Warning Message
This card has been deleted. CTC will return to the shelf
view.
ALS will not engage until both the protected trunk ports
detect LOS.
Performing a software upgrade while TSC 5 is active
could result in a service disruption. It is recommended
that you make TSC 10 the active TSC by performing
a soft reset of TSC 5. The following ONS 15600s are
currently unsafe to upgrade...
Before activating a new version, ensure that you have
a database backup from the current version.
Reverting to an older version.
Applying FORCE or LOCKOUT operations might
result in traffic loss.
The ring status is INCOMPLETE. CTC cannot
determine if there are existing protection operations or
switches in other parts of the ring. Applying a protection
operation at this time could cause a traffic outage.
Please confirm that no other protection operations or
switches exist before continuing.
There is a protection operation or protection switch
present on the ring. Applying this protection operation
now will probably cause a traffic outage.
The status of this ring is INCOMPLETE. CTC will not
be able to apply this change to all of the nodes in the
{0}.
The specified provisionable patchcord(s) could not be
deleted.
The revertive behavior cannot be changed because a
protection switch is active.
An error occurred while resetting the shelf.
No such provisionable patchcords exists.
Description
CTC returns to node view.
Refer to the warning message text.
Refer to the warning message text.
Refer to the warning message text.
CTC is being reverted to an older
version of application.
Refer to the warning message text.
Refer to the warning message text.
Refer to the warning message text.
Change the ring status to apply the
change to all nodes in the ring type.
Refer to the error message text.
Protection switch should not be active
to change the revertive behavior.
CTC encountered an error while
resetting the node.
You are attempting to delete a
provisionable patchcord that does not
exist. This happens when multiple
instances of CTC are running and
attempting to delete the same
provisionable patchcord concurrently.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
Error Messages Reference
511