Oduk-Oci-Pm - Cisco NCS 2000 series Troubleshooting Manual

Hide thumbs Also See for NCS 2000 series:
Table of Contents

Advertisement

Alarm Troubleshooting

ODUK-OCI-PM

Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
Logical Object: TRUNK
The ODUK Open Connection Indication (OCI) PM condition applies to TXP_MR_10G, TXP_MR_2.5G,
TXPP_MR_2.5G, TXP_MR_10E, TXP_MR_10E_C, TXP_MR_10E_L, MXP_2.5G_10G, ADM-10G, and
OTU2_XP cards when ITU-T G.709 encapsulation is enabled for the cards. It indicates that the upstream
signal is not connected to a trail termination source. The error is read as a STAT bit in the path monitoring
area of the digital wrapper overhead. ODUK-OCI-PM causes a downstream
alarm.
Clear the ODUK-OCI-PM Condition
SUMMARY STEPS
1. Verify the fiber connectivity at nodes upstream.
DETAILED STEPS
Verify the fiber connectivity at nodes upstream.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
ODUK-SD-PM
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: TRUNK
The ODUK Signal Degrade (SD) PM condition applies to TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G,
TXP_MR_10E, TXP_MR_10E_C, TXP_MR_10E_L, MXP_2.5G_10G, ADM-10G, and OTU2_XP cards
when ITU-T G.709 encapsulation is enabled. ODUK-SD-PM indicates that incoming signal quality is poor,
but the incoming line BER has not passed the fail threshold. The BER problem is indicated in the path
monitoring area of the optical data unit frame overhead.
Clear the ODUK-SD-PM Condition
SUMMARY STEPS
1. Complete the
Clear the OTUK-SD Condition, on page 345
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
ODUK-LCK-PM , on page 318
http://www.cisco.com/c/en/us/support/index.html
procedure.
ODUK-OCI-PM