Eqpt-Fpga-Image-Available - Cisco NCS 2000 series Troubleshooting Manual

Hide thumbs Also See for NCS 2000 series:
Table of Contents

Advertisement

EQPT-FPGA-IMAGE-AVAILABLE

If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
EQPT-FPGA-IMAGE-AVAILABLE
Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
Logical Object: EQPT
The EQPT-FPGA-IMAGE-AVAILABLE condition occurs when there is a mismatch between the running
trunk FPGA version and the package version.
Clear the EQPT-FPGA-IMAGE-AVAILABLE Condition
Perform a manual FPGA upgrade.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
EQPT-MISS
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: FAN
The Replaceable Equipment or Unit Missing alarm is reported against the fan-tray assembly unit. It indicates
that the replaceable fan-tray assembly is missing or is not fully inserted. It could also indicate that the ribbon
cable connecting the AIP to the system board is bad.
Caution
Always use the supplied electrostatic discharge wristband when working with a powered NCS system. Plug
the wristband cable into the ESD jack located on the lower-right edge of the shelf assembly.
Clear the EQPT-MISS Alarm
SUMMARY STEPS
1. If the alarm is reported against the fan, verify that the fan-tray assembly is present.
2. If the fan-tray assembly is present, complete the
3. If no fan-tray assembly is present, obtain a fan-tray assembly and refer to the Install the Fan-Tray Assembly
procedure in the Hardware Installation Guide.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
184
http://www.cisco.com/c/en/us/support/index.html
http://www.cisco.com/c/en/us/support/index.html
Replace the Fan-Tray Assembly, on page 460
Alarm Troubleshooting
procedure.