Alarm Troubleshooting
Note
This alarm does not apply to EdgeNN ports.

Clear the REP-NEIHB-ADJ-FAIL Alarm

SUMMARY STEPS
1. The alarm is cleared as soon as adjacency is established.
DETAILED STEPS
The alarm is cleared as soon as adjacency is established.
REP-SEGMENT-FAULT
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Objects: ETH, GE
The REP-SEGMENT-FAULT alarm is raised when a segment failure is detected in the following possible
scenarios:
• The link between two REP peer ports is down.
• The switch within the REP segment is down.
• REP protocol failure is present on the switch within the REP segment.
The alarm is raised at all REP ports across all switches participating in the impacted REP segment.
Clear the REP-SEGMENT-FAULT Condition
SUMMARY STEPS
1. The REP-SEGMENT-FAULT alarm is cleared once the segment is complete.
DETAILED STEPS
The REP-SEGMENT-FAULT alarm is cleared once the segment is complete.