BP-LPBKTERMINAL
DETAILED STEPS
Step 1
Log in to a node on the network.
Step 2
In node view (single-shelf mode) or shelf view (multishelf mode), double-click the 100G-LC-C or 10x10G-LC card in
CTC to open the card view.
Step 3
Click the Maintenance > Card tabs.
Step 4
Click on the card port that is in IS (or Unlocked) state in the Admin State column, and change the state to OOS,MT.
Step 5
Click Apply.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
BP-LPBKTERMINAL
Default Severity: Not alarmed (NA)
Logical Object: EQPT
The BP-LPBKTERMINAL alarm is raised when the backplane terminal loopback is configured on the
100G-LC-C or 10x10G-LC card.
Clear the BP-LPBKTERMINAL Alarm
Remove the backplane terminal loopback on the 100G-LC-C or 10x10G-LC card.
SUMMARY STEPS
1. Log in to a node on the network.
2. In node view (single-shelf mode) or shelf view (multishelf mode), double-click the 100G-LC-C or
10x10G-LC card in CTC to open the card view.
3. Click the Maintenance > Card tabs.
4. Click on the card port that is in IS (or Unlocked) state in the Admin State column, and change the state
to OOS,MT.
5. Click Apply.
DETAILED STEPS
Step 1
Log in to a node on the network.
Step 2
In node view (single-shelf mode) or shelf view (multishelf mode), double-click the 100G-LC-C or 10x10G-LC card in
CTC to open the card view.
Step 3
Click the Maintenance > Card tabs.
Step 4
Click on the card port that is in IS (or Unlocked) state in the Admin State column, and change the state to OOS,MT.
Step 5
Click Apply.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
146
http://www.cisco.com/c/en/us/support/index.html