Alarm Troubleshooting

OTDR-OTDR-TRAINING-FAILED-TX

Default Severity: NA
Logical Object: EQUIPMENT
The OTDR-OTDR-TRAINING-FAILED-TX alarm is raised if the training phase cannot find valid calibration
data.
Clear the OTDR-OTDR-TRAINING-FAILED-TX Alarm
Execute the training scan in the TX direction.
Note
If the scan shows high reflections, clean the connectors where the reflections are too high or change the
corresponding patchcords.
If the alarm does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-SCAN-FAILED
Default Severities: Major (MJ), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Optical Time Domain Reflectometer (OTDR) scan failed alarm is raised when the OTDR scan fails and
no result is sent to the user.
Clear the OTDR-SCAN-FAILED Alarm
This alarm is automatically cleared when no failed scan remains on for all sectors of the target PPM.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-SCAN-IN-PROGRESS
Default Severity: Minor (MI), Non-Service-Affecting (NSA)
Logical Objects: PPM
The Optical Time Domain Reflectometer (OTDR) Scan In Progress condition occurs under one of the following
conditions: