Otdr-Absolute-A-Exceeded-Rx - Cisco NCS 2000 series Troubleshooting Manual

Hide thumbs Also See for NCS 2000 series:
Table of Contents

Advertisement

OTDR-ABSOLUTE-A-EXCEEDED-RX

DETAILED STEPS
Turn the OSRI off:
a) In node view (single-shelf mode) or shelf view (multishelf mode), double-click the card to open the card view.
b) Click the Maintenance > ALS tabs.
c) In the OSRI column, choose OFF from the drop-down list.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-ABSOLUTE-A-EXCEEDED-RX
Default Severities: Major (MJ), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Optical Time Domain Reflectometer (OTDR) Absolute Attenuation Threshold Exceeded in Rx direction
alarm is raised when the attenuation event in the last scan exceeds the absolute threshold in the Rx direction.
Clear the OTDR-ABSOLUTE-A-EXCEEDED-RX Alarm
The alarm is cleared automatically when one of the following conditions is satisfied in the last scan:
• The attenuation event causing the alarm disappears.
• The attenuation event in the last scan is below the threshold.
• The absolute check is deactivated.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-ABSOLUTE-A-EXCEEDED-TX
Default Severities: Major (MJ), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Optical Time Domain Reflectometer (OTDR) Absolute Attenuation Threshold Exceeded in Tx direction
alarm is raised when the attenuation event in the last scan exceeds the absolute threshold in Tx direction.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
328
http://www.cisco.com/c/en/us/support/index.html
http://www.cisco.com/c/en/us/support/index.html
Alarm Troubleshooting