25 - 6
EMISSION CONTROL SYSTEMS
DESCRIPTION AND OPERATION (Continued)
MIL
HEX CODE
CODE
30
62*
31
63**
39
23**
3A
3B
16*
3C
61**
3D
27**
3E
21**
44
53**
45
27**
46
52
77*
57
87
5A
33
5B
5C
35**
5D
60**
66
GENERIC
SCAN
DRB SCAN TOOL
TOOL
DISPLAY
CODE
P1697
PCM Failure SRI
Miles Not Stored
P1696
PCM Failure
EEPROM Write
Denied
P0112
Intake Air Temp
Sensor Voltage Low
or
P0113
Intake Air Temp
Sensor Voltage High
Knock Sensor #1
Circuit
P0106
Barometric Pressure
Out Of Range
P0204
Injector #4 Control
Circuit
P0132
Right Rear (or just)
Upstream O2S
Shorted to Voltage
P0600
PCM Failure SPI
Communications
P0205
Injector #5 Control
Circuit
or
P0206
Injector #6 Control
Circuit
SPD CTRL PWR RLY;
or S/C 12v Driver
CKT
Speed Control Switch
Always Low
A/C Pressure Sensor
Volts Too High
or
A/C Pressure Sensor
Volts Too Low
P1490
Low Speed Fan CTRL
Relay Circuit
or
P1489
Hi Speed Fan Relay
Circuit
P1698
No CCD Messages
From TCM
DESCRIPTION OF DIAGNOSTIC TROUBLE
CODE
Unsuccessful attempt to update EMR mileage
in the PCM EEPROM
Unsuccessful attempt to write to an EEPROM
location by the PCM.
Intake air temperature sensor input below the
maximum acceptable voltage.
Intake air temperature sensor input above the
minimum acceptable voltage.
Sensor is either shorted to ground or 12 volts.
Will not detect open circuit.
MAP sensor has a baro reading below an
acceptable value.
Injector #4 output driver does not respond
properly to the control signal.
Oxygen sensor input voltage maintained above
the normal operating range.
PCM Internal fault condition detected.
Injector #5 output driver does not respond
properly to the control signal.
Injector #6 output driver does not respond
properly to the control signal.
Malfunction detected with power feed to speed
control servo solenoids.
Speed control switch input below the minimum
acceptabale voltage.
Sensor input voltage is above 4.9 volts.
Sensor input voltage is below .098 volts.
An open or shorted condition detected in the
control circuit of the low speed radiator fan
relay.
An open or shorted condition detected in the
control circuit of the high speed radiator fan
relay.
No messages received from Transmission
Control Module.
JX