Analog Monitor Connector Specifications (CN5)

Monitor Output Signal Table
Monitor output (CN5)
Pin
Symbol
Number
1
AM1
2
AM2
3
GND
4
5
6
Connectors for CN5 (6 Pins)
Name
Connector housing
Connector terminal
Monitor Output Circuit
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Name
Analog monitor output 1
Analog monitor output 2
Analog monitor ground
Not used
Not used
Not used
Model
51004-0600
50011-8000
Servo Drive
1 kΩ
+
3-1 Servo Drive Specifications
Function and interface
Outputs the analog signal for the monitor.
Default setting: Motor rotation speed 1 V/(500 r/min)
You can use Pn416 and Pn417 to change the item and
unit.
You can use Pn421 to change the output method.
Outputs the analog signal for the monitor.
Default setting: Torque command, 1 V/(33%)
You can use Pn418 and Pn419 to change the item and
unit.
You can use Pn421 to change the output method.
Ground for analog monitors 1, 2
Do not connect.
Do not connect.
Do not connect.
Manufacturer
Molex Japan
Molex Japan
1/2 AM1/AM2
Monitor equipment
3 GND
3
3-54