Unit Details
Symbol
Name
SG
Surge absorber
NF
Noise filter
SD
Servo Drive
SM
Servomotor
FC1
Clamp core
FC2
Clamp core
FC3
Clamp core
−
Controller
*1. A specified combination of Servo Drive and Servomotor must be used.
R88D-KT75H/-KT150H with DC Power Supply Input
(1)
Three-phase :
FC2
200 VAC
*1
SG
Single-phase :
100 VAC
(8)
Note. The main circuit power supply input terminals are L1 and L3. Connect the positive line to L1 and
the negative line to L3.
Ground the motor's frame to the machine ground when the motor is on a movable shaft.
Use a ground plate for the frame ground for each Unit, as shown in the above diagrams,
and ground to a single point.
Use ground lines with a minimum thickness of 3.5 mm
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
4-3 Wiring Conforming to EMC Directives
Manufacturer
Okaya Electric
R·A·V-781BXZ-4
Industries Co., Ltd.
SUP-EK5-ER-6
3SUP-HU10-ER-6
Okaya Electric
Industries Co., Ltd.
3SUP-HU30-ER-6
3SUP-HL50-ER-6B
FS5559-60-34
Schaffner EMC Inc.
FS5559-80-34
−
OMRON
−
OMRON
TDK
ZCAT3035-1330
RJ8035
Konno Industry
RJ8095
MICROMETALS
T400-61D
TDK
ZCAT3035-1330
−
−
FC1
+
L1
AC/
NF
L2
DC
−
L3
L1C
L2C
(6)
FC1
(5)
(7)
Controller
Model
3-phase 200 VAC
Single-phase 100/200 VAC (5 A)
3-phase 200 VAC (10 A)
3-phase 200 VAC (30 A)
3-phase 200 VAC (50 A)
3-phase 200 VAC (60 A)
3-phase 200 VAC (80 A)
*1
*1
−
−
For R88D-KT75H/-KT150H
For other models
−
FC3
SD
U
CNA
V
CNB
W
FC1
CN2
CN1
2
, and arrange the wiring so that the
Comment
(3)
(4)
SM
4-34
4