Omron R88M-K Series User Manual page 302

Ac servomotors/servo drives
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

4-3 Wiring Conforming to EMC Directives
Unit Details
Symbol
SG
NF
SD
SM
FC1
FC2
FC3
4
*1. A specified combination of Servo Drive and Servomotor must be used.
R88D-KT06F/-KT10F/-KT15F/-KT20F/-KT30F/-KT50F/-KT75F/-KT150F
3-phase:
400 VAC
Single-phase :
100 VAC
4-35
ground lines are as short as possible.
 A no-fuse breaker, surge absorber, and noise filter should be positioned near the input
terminal block (ground plate), and I/O lines should be separated and wired at the shortest
distance.
Name
Manufacturer
Okaya Electric
Surge absorber
Industries Co., Ltd.
Noise filter
Schaffner EMC Inc. FN258-42-07
Servo Drive
OMRON
Servomotor
OMRON
Clamp core
TDK
Clamp core
Konno Industry
Clamp core
MICROMETALS
Controller
(2)
(1)
NF
24 V
SG
DC
(6)
(5)
(8)
Controller
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Model
R·A·V-781BXZ-4
ZCAT3035-1330
RJ8095
T400-61D
FC2
SD
L1
CNA
L2
CNB
L3
FC1
L1C
L2C
FC1
CN1
CN2
(7)
Comment
3-phase 200 VAC
3-phase 200 VAC (42 A)
*1
*1
FC3
(3)
U
V
W
(4)
FC1
SM

Hide quick links: