Omron R88M-K Series User Manual page 607

Ac servomotors/servo drives
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

Parameter
name
Switching Mode
124
in Torque
Control
Gain Switching
125
Delay Time in
Torque Control
Gain Switching
126
Level in Torque
Control
Gain Switching
127
Hysteresis in
Torque Control
Note 1: The default setting is 320 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 2: The default setting is 180 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 3: The default setting is 310 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 4: The default setting is 126 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 5: The default setting is 380 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 6: The default setting is 180 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
Note 7: The default setting is 126 for 200-V Servo Drives of 1 kW or higher, and 400-V Servo
Drives.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Description
Select the gain switching condition for
torque control.
It is necessary that Pn114 be set to 1.
0
Always gain 1
1
Always gain 2
Switching using gain switching input
2
(GSEL)
3
Torque command change amount
Set the delay time for switching from gain 2
to gain 1.
Set the gain switching level.
Set the hysteresis for gain switching.
12-2 Parameter List
Default
Setting
Unit
setting
range
0
0 to 3
0 to
0
0.1 ms
10,000
0 to
0
20,000
0 to
0
20,000
12-16
Power
supply
OFF to
ON
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents