Omron R88M-K Series User Manual page 278

Ac servomotors/servo drives
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

4-2 Wiring
R88D-KT30H/-KT50H
Ground to 100 Ω or less.
4
Reactor
Regeneration
Resistor
24 VDC
User-side
control
device
4-11
R
S
T
3-phase 200 to 230 VAC, 50/60 Hz
NFB
Noise filter (*1)
1
2
3
NF
E
Main circuit power supply
4
5
6
OFF
X
OMNUC G5-series
AC Servo Drive
TB1
L1C
L2C
1MC
TB1
L1
L2
L3
B1
(*4)
B3
B2
CN1
X
37
/ALM
36
ALMCOM
X
CN1
Control cables
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Main circuit contactor (*1)
X
ON
Surge suppressor (*1)
1MC
Servo alarm display
XB
TB1
24 VDC
U
V
W
Ground to 100 Ω or less
CN2
Encoder cables
CN1
24 VDC
XB
BKIR
11
(*2)
BKIRCOM
10
1MC
PL
OMNUC G5-series
AC Servomotor
Power cables
(*3)
*1. Recommended products are listed in 4-3
Wiring Conforming to EMC Directives.
*2. Recommended relay: MY relay by
OMRON (24-V)
For example, MY2 relay by OMRON can
be used with all G5-series motors with
brakes because its rated induction load
is 2 A (24 VDC).
*3. There is no polarity on the brakes.
*4. The Built-in Regeneration Resistor
(KT30H and KT50H) connects B2 and
B3. When the amount of regeneration is
large, remove the connection between
B2 and B3 and connect the
Regeneration Resistor between B1 and
B2.
B
M
E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents