Analog Input Automatic Offset Adjustment
This performs automatic adjustment on the Offset Values (Pn422, Pn425 and Pn428) of
Analog Inputs 1 to 3 (AI1 to AI3).
Do not perform this operation if a position loop has been configured with the host system.
1. Execute automatic offset adjustment
Key
operation
2. Returning to Auxiliary Function Mode display
Key
operation
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Display example
Press the
Adjustment Mode from the alarm clear display in the Auxiliary
or
Function Mode.
or
Press the
Mode of the analog input number to be set.
or
or
Press and hold the
or
or
The bar indicator will increase.
Automatic offset adjustment will start.
This indicates a normal completion.
could not be performed. Set a valid control mode or make the
setting so that the offset value does not exceed the range for the
Speed Command Offset Value (Pn422, Pn425, or Pn428), and
then execute the procedure again.
Display example
Press the
or
or
9-4 Setting the Mode
Explanation
key to display the Analog Input Automatic Offset
key to enter the Automatic Offset Adjustment
key for 5 seconds or longer until
is displayed.
will be displayed if the automatic offset adjustment
Explanation
key to return to Auxiliary Function Mode.
9