Omron R88M-K Series User Manual page 515

Ac servomotors/servo drives
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

Analog Input Value
Input signal Input voltage (V)
Press
Note. Voltages exceeding +/−10 V are not displayed accurately.
Alarm Factor, History
...Present alarm
...History 0 (latest history)
...History 13 (oldest history)
 Up to the most recent 14 alarms, including the current one, can be viewed in the reason of error.
 The display area will flash when an alarm occurs.
 If an alarm that is recorded in the history occurs, the alarm code for the current alarm and for
history 0 will be the same.
 "st" will flash on the display if a safety input error (alarm 30.0) occurs.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
to select the signal you want to monitor.
Analog input value 1 (V)
The value after offset compensation is displayed.
Analog input value 2 (V)
Analog input value 3 (V)
Alarm code
(
if no alarm is present)
9-4 Setting the Mode
9-12