Omron R88M-K Series User Manual page 528

Ac servomotors/servo drives
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

9-4 Setting the Mode
Auxiliary Function Mode
Auxiliary Function Mode includes the alarm clear, analog input automatic offset adjustment,
absolute encoder reset, jog operation, parameter initialization, and front panel lock/release.
Displaying Auxiliary Function Mode
operation
Alarm Clear
This releases the alarm generation status.
Some alarms cannot be released. Refer to "11-3 Alarm List" (P.11-5) for details.
1. Execute alarm clear
operation
9
2. Returning to Auxiliary Function Mode display
operation
9-25
Key
Display example
Key
Display example
Key
Display example
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Explanation
The item set for the Default Display (Pn528) is displayed.
Press the
key to display Monitor Mode.
Press the
key 3 times to display Auxiliary Function Mode.
Explanation
Press the
key to enter Alarm Clear Mode.
Press and hold the
key for 5 seconds or longer until
is displayed.
The bar indicator will increase.
Alarm clear will start.
This indicates a normal completion.
will be displayed if the alarm could not be cleared.
Reset the power supply to clear the alarm.
Explanation
Press the
key to return to Auxiliary Function Mode.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents