R88D-KT20H
Main Circuit Connector Specifications (CNA)
Symbol
L1
Main circuit power
supply input
L2
L3
L1C
Control circuit power
supply input
L2C
Motor Connector Specifications (CNB)
Symbol
U
Motor connection
terminals
V
W
External Regeneration Resistor Connector Specifications (CNC)
Symbol
External Regeneration
B1
Resistor connection
B3
terminals
B2
NC
Do not connect.
Precautions for Correct Use
Tighten the ground screws to the torque of 0.7 to 0.8 N•m (M4) or 1.4 to 1.6 N•m (M5).
Never connect an External Regeneration Resistor between the B1 and NC terminals.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Name
R88D-KT@H (2 kW) :
3-phase: 200 to 230 VAC (170 to 253 V) 50/60 Hz
R88D-KT@H : Single-phase 200 to 230 VAC (170 to 253 V) 50/60
Hz
Name
Phase U
Phase V
Phase W
Name
Normally B2 and B3 are shorted. Do not short B1 and B2. Doing
so may cause malfunctions.
If there is high regenerative energy, remove the short-circuit bar
between B2 and B3 and connect an External Regeneration
Resistor between B1 and B2.
3-1 Servo Drive Specifications
Function
Function
These are the output terminals to the Servomotor.
Be sure to wire them correctly.
Function
3
3-10