Omron R88M-K Series User Manual page 364

Ac servomotors/servo drives
Hide thumbs Also See for R88M-K Series:
Table of Contents

Advertisement

5-6 Fully-closed Control
External Feedback Pulse Type Selection (Pn323, Pn326)
Set the external encoder output type and direction.
Parameter
number
Pn323
Pn326
5
<
5-31
Parameter name
External
Select the type of the external encoder to be
Feedback Pulse
used.
Type Selection
Set value
0
1
2
External
If the count directions of the external encoder
Feedback Pulse
feedback pulse and the encoder total
Direction
feedback pulses do not match, reverse the
Switching
external encoder feedback pulse direction in
this setting.
0: Not reversed, 1: Reversed
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Explanation
External encoder type
90° phase difference output
type
Incremental encoder with serial
communications
Reserved (Do not use this
setting.)
Setting
Unit
range
0 to 2
0 or 1