Pn310
No. 7 Internally Set Speed
Setting
−20,000 to 20,000
range
Pn311
No. 8 Internally Set Speed
Setting
−20,000 to 20,000
range
 If internal speed settings are enabled in the Command Speed Selection (Pn300), set the No. 1 to
4 internally set speed in Pn304 to Pn307 and the No. 5 to 8 internally set speed in Pn308 to Pn311.
Set the speed in r/min.
The polarity of the set values indicates the polarity of the internally set speed.
The forward direction as
+
viewed from the shaft end
The reverse direction as
viewed from the shaft end
 The absolute value of the parameter setting is limited by the Overspeed Level Setting (Pn513).
Pn312
Soft Start Acceleration Time
Setting
0 to 10,000
range
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Unit
r/min
Unit
r/min
Unit
ms/(1,000 r/min)
8-4 Analog Control Parameters
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
Speed
Speed
Speed
8