Pn615
Overspeed Detection Level Setting at Immediate Stop
Setting
0 to 20,000
range
Set overspeed detection level upon generation of immediate stop alarm.
The overspeed detection level setting will be 1.2 times the maximum motor rotation speed if this
parameter is set to 0.
This parameter should normally be set to 0. The setting should be changed only when it is
necessary to lower the overspeed detection level.
The set value of this parameter is limited to 1.2 times the maximum motor rotation speed.
Pn616
Absolute Interface Function Selection
Setting
0 or 1
range
Explanation of Set Values
Set value
0
Disabled
1
Enabled
Set this parameter to 1.
Pn617
Front Panel Parameter Write Selection
Setting
0 or 1
range
Explanation of Set Values
Set value
0
EEPROM write not performed when a parameter is changed from the front panel
1
EEPROM write performed at the same time
Set the EEPROM write conditions when the front panel parameter is changed.
Pn618
Power Supply ON Initialization Time
Setting
0 to 100
range
Set initialization time after power supply ON to the standard 1.5 seconds plus some.
Pn619
Encoder Phase-Z Setting
Setting
0 to 32,767
range
Finely adjust the ON width of encoder phase-Z signal output.
This is enabled when the phase-Z output and phase-A output are not synchronized (Pn011/Pn503
× Encoder resolution is not a multiple of 4) due to the encoder dividing ratio setting.
The set value of Pn619 and the ON width of phase-Z output are related as follows:
Phase-Z output width [s] = 30/(Pn619 × Motor speed [r/min])
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Unit
r/min
−
Unit
Explanation
−
Unit
Explanation
Unit
0.1 s
Unit
Pulse
8-7 Special Parameters
Default
Power OFF
0
setting
and ON
Default
Power OFF
1
setting
and ON
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
Default
Power OFF
0
setting
and ON
All
−
All
Yes
All
Yes
8
All
Yes
All
Yes
8-62