Servo Drive Life Expectancy
The lifetimes for the different drive parts are listed below.
Aluminum electrolytic capacitors:
(at an ambient drive operating temperature of 55°C, constant output of rated torque, constant
output of rated rotation speed, and installation as described in this manual)
Axial-flow fan: 10,000 to 30,000 hours (The limit depends on the operating conditions.)
Inrush current prevention relay: Approx. 20,000 operations (The limit depends on the operation
conditions.)
When using the Servo Drive in continuous operation, use fans or air conditioners to maintain the
ambient temperature below 40°C.
We recommend that ambient temperature and the power supply ON time be reduced as much the
possible to lengthen the service life of the Servo Drive.
The limit of aluminum electrolytic capacitors is greatly affected by the ambient operating
temperature. Generally, an increase of 10°C in the operating ambient temperature will reduce
capacitor service life by 50%. Following equation shows an example for 25°C: .
The aluminum electrolytic capacitors deteriorate even when the Servo Drive is stored with no
power supplied. If the Servo Drive is not used for a long time, we recommend periodic inspection
and a part replacement period of 5 years.
If the Servomotor or Servo Drive is not to be used for a long time, or if they are to be used under
conditions worse than those described above, a periodic inspection period of 5 years is
recommended.
Upon request, OMRON will examine the Servo Drive and Servomotor and determine if part
replacement is required.
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
28,000 hours
Lifetime 25°C = Lifetime 55°C × 2
11-5 Periodic Maintenance
55−25
= 224000 hour
10
11
11-28