Grandstream Networks UCM6100 Series User Manual page 172

Ip pbx
Hide thumbs Also See for UCM6100 Series:
Table of Contents

Advertisement

Maximum  Call  Duration  
Warning  Time  
Warning  Repeat  Interval  
Privilege  Level  
Enable  Filter  on  Source  Caller  
ID  
Firmware  Version  1.0.9.26  
 
Configure   the   maximum   duration   of   the   call   (in   seconds).   The   default  
setting  is  0,  which  means  no  limite.  
Configure  the  warning  time  for  the  call  using  this  outbound  route.  If  set  to  
x  seconds,  the  warning  tone  will  be  played  to  the  caller  when  x  seconds  
are  left  to  end  the  call.  
Configure   the   warning   repeat   interval   for   the   call   using   this   outbound  
route.  If  set  to  x  seconds,  the  warning  tone  will  be  played  every  x  seconds  
after  the  first  warning.  
Select  privilege  level  for  the  outbound  rule.  
Internal:  The  lowest  level  required.   A ll  users  can  use  this  rule.  
•  
Local:  Users  with  Local,  National,  or  International  level  are  allowed  to  
•  
use  this  rule.  
National:  Users  with  National  or  International  level  are  allowed  to  use  
•  
this  rule.  
International:  The  highest  level  required.  Only  users  with  international  
•  
level  can  use  this  rule.  
Disable:  The  default  setting  is  "Disable".  If  selected,  only  the  matched  
•  
source  caller  ID  will  be  allowed  to  use  this  outbound  route.  
 
Please  be  aware  of  the  potential  security  risks  when  using  "Internal"  level,  
which   means   all   users   can   use   this   outbound   rule   to   dial   out   from   the  
trunk.  
When   enabled,   users   could   specify   extensions   allowed   to   use   this  
outbound   route.   "Privilege   Level"   is   automatically   disabled   if   using  
"Enable  Filter  on  Source  Caller  ID".  
The  following  two  methods  can  be  used  at  the  same  time  to  define  the  
extensions  as  the  source  caller  ID.  
1.   Select  available  extensions/extension  groups  from  the  left  to  the  right.  
This  allows  users  to  specify  arbitrary  single  extensions  available  in  
the  PBX.  
2.   Custom  Dynamic  Route:  define  the  pattern  for  the  source  caller  ID.  
This  allows  users  to  define  extension  range  instead  of  selecting  them  
one  by  one.  
All  patterns  are  prefixed  with  the  "_".  
•  
Special  characters:    
•  
X:   A ny  Digit  from  0-­9.  
Z:   A ny  Digit  from  1-­9.  
N:   A ny  Digit  from  2-­9.  
".":  Wildcard.  Match  one  or  more  characters.  
"!":  Wildcard.  Match  zero  or  more  characters  immediately.  