CC  Mode  
CC  Max   A gents  
CC  Max  Monitors  
Ring  Simultaneously  
Ring  Simultaneously  
External  Number  
Time  Condition  for  Ring  
Simultaneously  
Other  Settings  
Ring  Timeout  
Auto  Record  
Skip  Trunk   A uth  
Firmware  Version  1.0.9.26  
 
party  is  available,  given  that  a  previous  call  to  that  party  failed  for  some  
reason.  By  default  it's  disabled.  
Two  modes  for  Call  Completion  are  supported:  
Normal:  This  extension  is  used  as  ordinary  extension.  
•  
For  Trunk:  This  extension  is  registered  from  a  PBX.  
•  
The  default  setting  is  "Normal".  
Configure  the  maximum  number  of  CCSS  agents  which  may  be  allocated  
for   this   channel.   In   other   words,   this   number   serves   as   the   maximum  
number   of   CC   requests   this   channel   is   allowed   to   make.   The   minimum  
value  is  1.  
Configure   the   maximum   number   of   monitor   structures   which   may   be  
created  for  this  device.  In  other  words,  this  number  tells  how  many  callers  
may  request  CC  services  for  a  specific  device  at  one  time.  The  minimum  
value  is  1.  
Enable  this  option  to  have  an  external  number  ring  simultaneously  along  
with   the   extension.   If   a   register   trunk   is   used   for   outbound,   the   register  
number  will  be  used  to  be  displayed  for  the  external  number  as  caller  ID  
number.  
Set   the   external   number   to   be   rang   simultaneously.   '-­'   is   the   connection  
character  which  will  be  ignored.  
Ring  the  external  number  simultaneously  along  with  the  extension  on  the  
basis  of  this  time  condition.  
Configure   the   number   of   seconds   to   ring   the   user   before   the   call   is  
forwarded   to   voicemail   (voicemail   is   enabled)   or   hang   up   (voicemail   is  
disabled).   If   not   specified,   the   default   ring   timeout   is   60   seconds   on   the  
UCM6100,   which   can   be   configured   in   the   global   ring   timeout   setting  
under  web  GUI-­>Internal  Options-­>IVR  Prompt:  General  Preference.  The  
valid  range  is  between  5  seconds  and  600  seconds.  
Note:  
If  the  end  point  also  has  a  ring  timeout  configured,  the  actual  ring  timeout  
used  is  the  shortest  time  set  by  either  device.  
Enable  automatic  recording  for  the  calls  using  this  extension.  The  default  
setting   is   disabled.   The   recording   files   can   be   accessed   under   web  
GUI-­>CDR-­>Recording  Files.  
·   If   set   to   'yes',   users   can   skip   entering   the   password   when   making  
outbound  calls.    
·   If  set  to  'By  Time',  users  can  skip  entering  the  password  when  making  
UCM6100  Series  IP  PBX  User  Manual  
 
 
Page  126  of  304    