Kyocera KM-4230 Service Manual page 82

Hide thumbs Also See for KM-4230:
Table of Contents

Advertisement

Original feed timing
OFSOL A
OFSOL R
OFCL
Fwd. rotation
OFM
Off
Rev. rotation
OFSW
OSBSW
OCM
DFTSW
Timing chart 1-3-10 Original feed (in double-sided original mode)
A The OFSOL A signal turns on for 200 ms and then the original feed solenoid (OFSOL)
turns on, lowering the DF forwarding pulleys and releasing the original stopper to convey
the original forward. The original feed clutch (OFCL) simultaneously turns on, rotating
the DF original feed pulley to start primary original feed. The original feed motor (OFM)
rotates forward during this operation.
B 556 OFM pulses after the leading edge of the original turns the original feed switch
(OFSW) on, the original feed clutch (OFCL) and original feed motor (OFM) turn off. 20
ms later, the rotation of the motor switches to the reverse direction and secondary
original feed is performed by rotation of the DF registration roller.
C 288 OFM pulses plus 30 ms after the leading edge of the original turns the DF timing
switch (DFTSW) on, the original feed motor (OFM) turns off.
D After ejection of the original, as the original conveying motor (OCM) turns off, the OFSOL
R signal turns on for 200 ms and the original feed solenoid (OFSOL) turns off.
200 ms
556 P*
1
20 ms
A
B
200 ms
288 P*
2
+ 30 ms
C
D
*
1
Burst of OFM pulses
2
*
Burst of OCM pulses
2A3/4
1-3-59