Kyocera KM-4230 Service Manual page 432

Hide thumbs Also See for KM-4230:
Table of Contents

Advertisement

Code
Contents
C610
Broken fixing unit ther-
mistor wire
• The fixing temperature
does not increase for 40 s
after the fixing heaters
have been turned on for
warming up.
• The fixing temperature re-
mains below 50˚C/122˚F
for 10 s continuously after
the fixing heaters have
been turned on during sta-
bilization.
C620
Abnormally low fixing
temperature
• The fixing temperature re-
mains below 120˚C/248˚F
for 10 s.
Causes
Fixing unit
Check and reinstall if neces-
heater M or S
sary.
installed incor-
rectly.
Broken fixing
Check for continuity. If none,
unit heater M or
replace the fixing unit heater
S wire.
M or S.
Poor contact of
Check the connection of con-
the fixing unit
nector CN3-B8 on the engine
thermistor con-
PCB and the continuity across
nector termi-
the connector terminals. Re-
nals.
pair or replace if necessary.
Broken fixing
Measure the resistance. If it is
unit thermistor
infinite, replace the fixing unit
wire.
thermistor.
Fixing unit ther-
Check and reinstall if neces-
mistor installed
sary.
incorrectly.
Fixing unit ther-
Check for continuity. If none,
mostat trig-
replace the fixing unit thermo-
gered.
stat.
Fixing unit
Check and reinstall if neces-
heater M or S
sary.
installed incor-
rectly.
Broken fixing
Check for continuity. If none,
unit heater M or
replace the fixing unit heater
S wire.
M or S.
Remarks
Check procedures/
corrective measures
2A3/4
3-5-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-5230

Table of Contents