4. Fixing section
• Jam in fixing section (jam code 40)
The eject switch (ESW) does not turn on within 2552 ms of the registration clutch (RCL)
turning on.
RCL
ESW
5. Eject section
• Jam in eject section (jam code 50)
The eject switch (ESW) does not turn off within 2528 ms of turning on.
ESW
• Jam in switchback eject section (jam code 51)
The switchback eject switch (SBESW) does not turn off within 1470 ms of turning on.
SBESW
2552 ms
Timing chart 2-2-15
2528 ms
Timing chart 2-2-16
1470 ms
Timing chart 2-2-17
2A3/4
Off
On
Off
On
Off
On
Off
On
2-2-7