2A3/4
Self diagnostic codes
Code
Contents
C001
Memory copy PCB 1 com-
munication problem
• Problems with data from
memory copy PCB 1.
C003
Memory copy PCB 2 prob-
lem*
1
• Problems with data from
memory copy PCB 2.
C010
RAM/ROM problem
• Read and write data does
not match.
C011
Backup memory data
problem
• Data in the specified area
of the backup memory
does not match the speci-
fied values.
C021
Operation unit main PCB
communication problem
• There is no reply after 20
retries at communication.
*1: 42 ppm: optional/52 ppm: standard.
3-5-2
Causes
Defective
Replace memory copy PCB 1
memory copy
and check for correct opera-
PCB 1.
tion.
Defective
Replace memory copy PCB 2
memory copy
and check for correct opera-
PCB 2.
tion.
Defective main
Replace the main PCB and
PCB.
check for correct operation.
Problem with
Turn safety switch 1 off and
the backup
back on and run maintenance
memory data.
item U020 to set the contents
of the backup memory data
again.
Defective
If the C011 is displayed after
backup RAM.
re-setting the backup memory
contents, replace the backup
RAM.
Poor contact of
Check the connection of con-
the connector
nectors CN6 on the main PCB
terminals.
and CN6 on the operation unit
main PCB, and the continuity
across the connector termi-
nals. Repair or replace if nec-
essary.
Defective main
Replace the main PCB or op-
PCB or opera-
eration unit main PCB and
tion unit main
check for correct operation.
PCB.
Remarks