( 3 ) Detaching and refitting the drum separation claw assembly and cleaning
lower seal assembly.
Clean or replace the drum separation claw assembly and cleaning lower seal assembly
as follows.
<Procedure>
1. Remove the developing unit, main charger assembly and drum.
2. Remove the four screws holding the drum separation claw assembly and then the
assembly.
3. Remove the two screws holding the cleaning lower seal assembly and then the
assembly.
4. Replace the drum separation claw assembly and cleaning lower seal assembly.
Cleaning lower seal
assembly
Figure 3-3-74 Detaching the drum claw assembly
5. Refit all removed parts.
Screw
and cleaning lower seal assembly
Drum separation claw assembly
Screws
2A3/4
Screw
3-3-63