2A3/4
Code
Contents
C401
Polygon motor steady-
state problem
• The polygon motor rotation
is not stable for 600 ms af-
ter the polygon motor rota-
tion has been stabilized.
C420
BD steady-state problem
• The VTC detects a BD er-
ror for 600 ms after the
polygon motor rotation has
been stabilized.
C510
Main charger problem
• MC ALM signal is detected
continuously for 400 ms
when MC REM signal is
turned on.
C511
Transfer/separation high-
voltage problem
• STALM signal is detected
continuously for 400 ms
when TC/SC REM signal is
turned on.
C610
Broken fixing unit ther-
mistor wire
• The fixing temperature
does not increase for 40 s
after the fixing heaters
have been turned on for
warming up.
• The fixing temperature re-
mains below 50˚C/122˚F
for 10 s continuously after
the fixing heaters have
been turned on during sta-
bilization.
3-5-12
Causes
Defective
Check if 24 V DC is supplied
power source
to CN6-5 on the engine PCB.
PCB.
If not, replace the power
source PCB.
Defective en-
Check if 24 V DC is output
gine PCB.
from CN7-1 on the engine
PCB. If not, replace the engine
PCB.
Defective laser
Replace the LSU.
diode.
Defective poly-
Replace the LSU.
gon motor.
Defective main
Replace the main PCB.
PCB.
Defective high-
Replace the high-voltage
voltage trans-
transformer PCB.
former PCB.
Leakage during
Check and clean the main
main charging.
charger assembly.
Defective high-
Replace the high-voltage
voltage trans-
transformer PCB.
former PCB.
Leakage during
Check and clean the transfer
transfer/sepa-
charger assembly.
ration charging.
Poor contact of
Check the connection of con-
the fixing unit
nector CN3-B8 on the engine
thermistor con-
PCB and the continuity across
nector termi-
the connector terminals. Re-
nals.
pair or replace if necessary.
Broken fixing
Measure the resistance. If it is
unit thermistor
infinite, replace the fixing unit
wire.
thermistor.
Fixing unit ther-
Check and reinstall if neces-
mistor installed
sary.
incorrectly.
Fixing unit ther-
Check for continuity. If none,
mostat
replace the fixing unit thermo-
triggered.
stat.