2A3/4
• Multiple sheets before registration section (jam code 23)
The feed switch (FSW) does not turn off within 1340 ms of paper feed switch 1 (PFSW1)
turning off.
PFSW1
FSW
The feed switch (FSW) does not turn off within 2528 ms of turning on during bypass
paper feed.
FSW
3. Paper conveying section
• Jam in registration/transfer section (jam code 30)
The registration switch (RSW) does not turn off within 764 ms of the feed switch (FSW)
turning off.
FSW
RSW
2-2-6
1340 ms
Timing chart 2-2-12
2528 ms
Timing chart 2-3-13
764 ms
Timing chart 2-2-14
Off
On
Off
On
Off
On
Off
On
Off
On