Kyocera KM-4230 Service Manual page 425

Hide thumbs Also See for KM-4230:
Table of Contents

Advertisement

2A3/4
Code
Contents
C200
Drive motor problem
• DM LOCK signal remains
high for 1 s, 1 s after the
drive motor has turned on.
C210
Paper conveying motor
problem
• PCM LOCK signal remains
high for 1 s, 1 s after the
conveying motor has
turned on.
3-5-6
Causes
Poor contact of
Reinsert the connector. Also
the drive motor
check for continuity within the
connector ter-
connector cable. If none, rem-
minals.
edy or replace the cable.
Defective drive
Replace the drive motor.
motor rotation
control circuit.
Defective drive
Check if the rollers and gears
transmission
rotate smoothly. If not, grease
system.
the bushings and gears.
Check for broken gears and
replace if any.
Poor contact of
Reinsert the connector. Also
the paper con-
check for continuity within the
veying motor
connector cable. If none, rem-
connector ter-
edy or replace the cable.
minals.
Defective paper
Replace the paper conveying
conveying mo-
motor.
tor rotation con-
trol circuit.
Defective drive
Check if the rollers and gears
transmission
rotate smoothly. If not, grease
system.
the bushings and gears.
Check for broken gears and
replace if any.
Remarks
Check procedures/
corrective measures

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-5230

Table of Contents