2A3/4
J When the side registration home position switch (SRHPSW) turns on, the side registration
motor (SRM) turns off.
K 500 ms after the side registration home position switch (SRHPSW) turns on, the side
registration motor (SRM) rotates forward to move the side registration guides inwards.
L When the side registration home position switch (SRHPSW) turns off, the side registration
motor (SRM) turns off.
M 500 ms after the side registration home position switch (SRHPSW) turns off, the side
registration motor (SRM) reverses for 5 pulses, and the side registration guide stops at
its home position.