Kyocera KM-4230 Service Manual page 247

Hide thumbs Also See for KM-4230:
Table of Contents

Advertisement

2A3/4
Maintenance
item No.
Setting the transfer voltage
U101
1 Change the setting using the Up/Down keys.
Display
Operation
TC DATA
Transfer control voltage
Increasing the setting makes the transfer voltage higher, and
decreasing it makes the voltage lower.
2 Press the print key. The value is set.
3 To check the transfer voltage output, press the TC ON on the touch
panel. The currently set transfer voltage is output.
4 To stop the transfer voltage output, press the stop/clear key.
5 To return to the screen for selecting an item, press the stop/clear key
after the transfer voltage output is stopped.
Setting the separation voltage
1 Change the setting using the Up/Down keys.
Display
Description
AC DATA
Separation control voltage
Increasing the setting makes the separation voltage higher, and
decreasing it makes the voltage lower.
2 Press the print key. The value is set.
3 To return to the screen for selecting an item, press the stop/clear key.
Interrupt copy mode
While this maintenance item is being performed, copying from an original
can be made in interrupt copy mode.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No.
is displayed.
3-2-38
Description
Setting range
0 to 255
Setting range
0 to 255
Initial setting
140
Initial setting
100