Maintenance
item No.
Setting
U099
1 Select an item to be set.
Display
LEVEL
WAIT TIME
ORIGINAL AREA
SIZE
* Time from activation of the original detection switch (ODSW) to
original size judgment
Method to set the detection threshold value
1 Adjust the preset value using the Up/Down keys.
* A larger value increases the sensor sensitivity, and a smaller value
decreases it.
2 Press the print key. The value is set.
3 To return to the screen for selecting an item, press the stop/clear key.
Method to set the original size judgment time
1 Adjust the preset value using the Up/Down keys.
* A larger value increases the original size judgment time, and a smaller
value decreases it.
2 Press the print key. The value is set.
3 To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for
maintenance item No. is displayed.
Description
Description
Detection sensor threshold value
Original size judgment time*
Original size detection position display (mm)
Detected original size display
2A3/4
3-2-35