Kyocera KM-4230 Service Manual page 452

Hide thumbs Also See for KM-4230:
Table of Contents

Advertisement

(5) A white line appears
longitudinally.
Causes
1. Dirty or flawed transfer charger
wire.
2. Foreign matter in the developing
section.
3. Flawed drum.
4. Dirty shading plate.
(6) A black line appears
longitudinally.
Causes
1. Dirty contact glass.
2. Dirty or flawed drum.
3. Deformed or worn cleaning blade.
4. Dirty scanner mirror.
Causes
1. Dirty or flawed transfer charger wire.
2. Foreign matter in the developing section.
3. Flawed drum.
4. Dirty shading plate.
Check procedures/corrective measures
Clean the transfer charger wire or, if it is
flawed, replace it.
Check if the magnetic brush is formed
uniformly. If not, replace the developer.
Replace the drum (see page 3-3-45).
Clean the shading plate.
Causes
1. Dirty contact glass.
2. Dirty or flawed drum.
3. Deformed or worn cleaning blade.
4. Dirty scanner mirror.
Check procedures/corrective measures
Clean the contact glass.
Clean the drum or, if it is flawed, replace it
(see page 3-3-45).
Replace the cleaning blade (see page
3-3-59).
Clean the scanner mirror.
2A3/4
3-6-7