13. Detach the round terminal of the scanner wire from the scanner wire spring on the
left side of the scanner unit.
14. Remove the scanner wire.
(2-2) Refitting the scanner wires
Caution: When fitting the wires, be sure to use those specified below.
Machine front: 2AC12170
Machine rear: 2AC12420 (black)
Refitting requires the following tool:
Frame securing tool (P/N: 2AC68230)
<Procedure>
At the machine rear:
1. Insert the two frame securing tools into the positioning holes at the front and rear of
the scanner unit to pin the mirror 2 frame in position.
2. Secure the two frame securing tools at the machine front and rear using the two
screws for each.
3. Hook the round terminal on one end of the scanner wire onto the left catch on the
inside of the scanner unit. ....................................................................................... 1
4. Loop the scanner wire around the rear groove in the scanner wire pulley on the
mirror 2 frame, winding from below to above. ........................................................ 2
5. Loop the scanner wire around the groove in the scanner wire pulley at the machine
right, winding from above to below. ........................................................................ 3
(Machine left)
6
Round
terminal
7
Figure 3-3-30 Detaching the scanner wire
Front groove
Wire guide
2
4
Scanner wire spring
Figure 3-3-31 Refitting the scanner wires
Scanner unit
Round terminal
Scanner wire spring
Rear groove
Catch
1
5
Round terminal
(Machine right)
Scanner wire pulley
3
Scanner
wire drum
2A3/4