( 2 ) Detaching and refitting the switchback roller, duplex upper registration roller
Replace the switchback roller and duplex registration roller as follows.
<Procedure>
• Detaching the switchback roller
1. Open the duplex unit.
2. Remove the two screws holding the duplex unit front cover and then the cover.
(only for 42 ppm)
3. Loosen the three screws at the front of the duplex unit. Remove the two screws on
the top and then the duplex unit cover.
Screws
Figure 3-3-95 Detaching the duplex unit cover
Duplex unit cover
Screws
*Illustration shows a 42 ppm.
2A3/4
Screws
Duplex unit front cover
3-3-81