7.16.23 Configuration System Set
CNSYS
Configuration System Set
This command is used to enter the system identity string, personality setting,
IP address of the converter, system reference number, and to turn on and off
certain features and signalling systems on the converter.
The personality parameter is used to select customer-specific, non-standard
operating functionality for the converter. To achieve the standard operating
functionality the personality should be set to the default value (i.e. zero). Unless
otherwise notified all customers should select the standard operating functionality.
When a password is specified all new MML sessions apart from serial port 1 will
require the password before entry.
After changing any parameter other than the system identity the system MML will
deny access to all configuration maintenance and status command with the
exception of the CNSYS, CNANI, CNUPI, STRDP and CNRDx commands. Access
to the alarm log and configuration print will also be allowed.
Prerequisites
When changing the personality or activating/deactivating signalling protocols all
boards and groups within the system must be blocked.
There must be no Remote Data Centres present when changing the remote data
centre allowed option.
After changing any parameter other than the system identity the system must be
restarted using the MNRSI command or by power cycling the unit.
The ISC option cannot be changed if the service is active elsewhere in the system.
Syntax
CNSYS:{[SYSID=,][PER=,][IPADDR=,][ISUP=,][NUP=,][Q931=,][DPNSS=,]
Attributes
CONFIG
Example
CNSYS:SYSID=STATION1,PER=2,IPADDR=255.123.0.123;
DataKinetics DSC110 / DSC210 User Manual Issue 12
[REMOTE=,][SYSREF=,][TUP=,][ISC=,][CLIAUTH=,][TRANS=,]
[ANNOUNCE=,][SUBNET=,][GATEWAY=,][PASSWORD=,];
Page 97