7.10.1 Configuration Update on Startup
Configuration data is updated by first cycling the power supply of the converter
(switched OFF, wait 5 seconds, then back ON) to cause a processor restart
(alternatively the user may cause a processor restart using the MNRSI command).
After the central processor starts up the three red alarm LEDs will flash off for a
period of five seconds. It is during this five second window that the configuration
disk should be placed in the floppy disk drive. The converter will identify the
configuration data on the disk as it starts up, and will load this into the internal
non-volatile memory before starting the main converter software.
7.10.2 Configuration Update from Floppy Disk
The procedure for a configuration update from floppy disk using MML will be as
follows
The user should enter:
CNUPI:DTYPE=CONFIG,FILE=<filename>;
to request that the configuration file be updated from floppy disk.
The configuration file <filename>.CF2 will uploaded from floppy disk.
Once all the disks have been read in by the user the user should restart the
system by cycling the power supply of the converter (switched OFF, wait 5
seconds, then back ON) to cause a processor restart (alternatively the user may
cause a processor restart using the MNRSI command).
7.10.3 Configuration Update from Remote Data Centre
The procedure for a configuration update the RDC will be as follows
The user should enter:-
CNUPI: DTYPE=CONFIG,RDC=<rdc id>,
DIRECTORY=< subdirectory>,FILE=<filename>;
to request that the configuration be updated from a RDC where the configuration
update file <filename.SD2> is stored in a subdirectory in the ftproot.
Once the user has confirmed that the configuration should be upgraded the
configuration file will be transferred to the converter without further interaction
with the user. The unit will indicate that the file has been successfully transferred
by displaying the "EXECUTED" response to the CNUPI command.
On completion the user should restart the system by cycling the power supply of
the converter (switched OFF, wait 5 seconds, then back ON) to cause a
processor restart (alternatively the user may cause a processor restart using the
MNRSI command).