7.15.2 Circuit Assignment Circuit Group Change
CACGC
Circuit Assignment Circuit Group Change
This command is used to change the attributes of a CGRP.
If a PCM is specified then the group will use the PCM's timeslots for voice/data
traffic.
Syntax
CACGC:CGRP=,
Prerequisites
If specified, the PCM must already have been initiated and the timeslots on the
PCM must not be already in use elsewhere on the system.
If specified, the point of origin must already be initiated.
The circuit group must be blocked unless only the label is changed.
PRI can only be entered for the Network Side or DPNSS on the Access Side.
If the POR is specified and the circuit group is circuit mapped to a far circuit group
the POR can only be changed if the far circuit group is blocked.
If the POR is specified and the POR goes to a route that is circuit mapped then the
POR can only be changed if the new partner group is blocked.
An E1 PCM cannot be changed to a T1 PCM if the devices on the group are outside
the range 1-24.
NUP and TUP circuit groups cannot be assigned a C7 route that has ANSI linksets.
NUP circuit groups cannot be assigned a C7 route that has 24 bit point codes.
COT cannot be set to a value other than zero except for TUP and ISUP.
Incoming COT check can only be set if there is a PCM present.
ENC can only be set if User to User Service 1 is set to Y.
TMRM can only be set to 2 if the circuit group is ISUP and is not ANSI.
Limitations
This command cannot be used to remove a PCM from a circuit group.
Attributes
CONFIG
Example
CACGC:CGRP=1,CC=3-5;
DataKinetics DSC110 / DSC210 User Manual Issue 12
[PCM=,][CPC=,][CC=,][POR=,][PRI=,][NTTYPE=,][L1=,][TMRM=,][INT=,]
[OHEC=,][IHEC=,][ENC=,][U2U=,][ISMD=,][COT=,][DCPC=,][DIV=,]
[TEXT=,]SAT=,][LABEL=,];