DataKinetics DSC110 User Manual page 75

Signalling converter
Table of Contents

Advertisement

7.13.3 Alarm Fault Code Print
ALFCP
Alarm Fault Code Print
This command gives a print-out of the alarm class of specified fault code(s).
Syntax:
ALFCP[:CODE=...];
Attributes:
None.
Example:
ALFCP;
ALFCP:CODE=8;
Output Format
Alarm Fault Codes
CODE
CLA
8
2
EXECUTED
7.13.4 Alarm List Print
ALLIP
Alarm List Print
This command gives a print-out of all ACTIVE fault codes stored in the system's
alarm log.
Syntax
ALLIP;
Attributes
None.
Example
ALLIP;
Output Format
SYSTEMIDENT1 Alarm List (active alarms) 1996-12-01 00:00:54
ALP
CODE ID DIAG CLA OCCURRED
107
1
0 0043 1 A 1994-10-30 10:54:48
74
20
0 1211 2 A 1994-10-30 10:54:27
EXECUTED
Note: The meaning of the ID field depends on the alarm code and is described in ANNEX A.
DataKinetics DSC110 / DSC210 User Manual Issue 12
TITLE
In-band AIS
CLEARED
TITLE
PCM loss
-12v fault
Page 75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsc210

Table of Contents