DataKinetics DSC110 User Manual page 169

Signalling converter
Table of Contents

Advertisement

Board cong
50
A board has reached a congestion
threshold. Boards repeatedly entering
congestion indicate a need to increase the
dimensioning of the switch.
TUP maint ind
51
Diagnostic event relating to NUP
functionality. Persistent events of this type
should be reported to DataKinetics.
TUP err ind
52
Diagnostic event relating to NUP
functionality. Persistent events of this type
should be reported to DataKinetics.
PCM mismatch
53
The PCMTYPE setting is inconsistent with
the hardware settings on the board.
DP4 event
54
Diagnostic event relating to DPNSS
functionality. Persistent events of this type
should be reported to DataKinetics.
DP3 event
55
Diagnostic event relating to DPNSS
functionality. Persistent events of this type
should be reported to DataKinetics.
DP2 event
56
Diagnostic event relating to DPNSS
functionality. Persistent events of this type
should be reported to DataKinetics.
DLC failure
57
Failure of 1 or more DLCs on a DPNSS
signalling link.
ANN event
58
Diagnostic event relating to Announcement
functionality. Persistent events of this type
should be reported to DataKinetics.
ANN error
59
Diagnostic event relating to Announcement
functionality. Persistent events of this type
should be reported to DataKinetics.
Announcement failure
60
The announcement WAV file has become
invalid. The indicated ANNC should be
removed.
SW mismatch
6
1
The system has only partially been
upgraded and a full software update is
required. The system is running in 'safe'
mode running limited management software.
No circuits have been brought into service.
C7 link Cong
62
A SS7 signalling link is encountering
congestion.
DataKinetics DSC110 / DSC210 User Manual Issue 12
BPOS
PCM
0
ASLINK
0
ANNC
0
0
0
C7LINK
0
Page 169
SYSTEM
NONE
NONE
SYSTEM
NONE
NONE
NONE
SIG
NONE
NONE
NONE
SYSTEM
SIG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsc210

Table of Contents